Description
Product Benefits
Dedicated Accuracy
BioSelect™ menu provides field selectable air, methane, and digester gas
Gases: ±2% of full scale
Measures gas flow rate in SCFM, MSCFD, KG/HR, and many more
DigiSense™ sensor design / Swivel probe ±180° into four positions
Wide measurement range up to 1000:1 turndown; 100:1 typical
Low-end sensitivity for leak detection
Negligible pressure drop
4-20mA for flow rate or temperature; HART communication option
Choice of second channel: Pulse output for flow / total or Modbus RTU (RS485)
FM (U.S.) and FMc (CANADA) approved for Class I, Div 1; ATEX/IECEx approved for Zone 1
NEMA 4X and CE Mark
Welded, 316 SS sensor and flow body construction, carbon steel flow body optional
Field Flexibility
Microprocessor based, field-programmable electronics
Optional on-board 2 line x 16 character, backlit display with configuration panel
Free BioView software available
USB port to connect to a PC is standard
Oxygen applications: Certified cleaning and bagging procedures are provided
BioCal calibration validation
NIST traceable calibration